Language

English

Publication Date

6-1-2026

Journal

Journal of Cataract & Refractive Surgery

DOI

10.1097/j.jcrs.0000000000001877

PMID

41559925

PMCID

PMC13200903

PubMedCentral® Posted Date

1-1-2026

PubMedCentral® Full Text Version

Post-print

Abstract

Purpose: To evaluate the correlation between the preoperative vertex-scleral spur angle (Vtx-SSA) and postoperative horizontal intraocular lens (IOL) tilt after routine cataract surgery.

Setting: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas.

Design: Prospective case series.

Methods: This study enrolled patients who underwent uneventful phacoemulsification cataract extraction with IOL implantation. The Anterion and Eyestar 900 swept-source optical coherence tomographers (SS-OCTs) were used to determine Vtx-SSA and lens tilt (crystalline and IOL) measurements, respectively. Tilt vectors were decomposed into orthogonal, vertical, and horizontal components to explore preoperative correlations independently. The Pearson correlation coefficient and linear regression analysis were used to evaluate the relationships between select variables.

Results: In a cohort of 72 eyes of 72 patients, the preoperative Vtx-SSA was highly correlated with horizontal IOL tilt ( r2 = 0.97, P < .01). On average, tilting of the IOL in the horizontal axis accounted for nearly 80% of the total tilt magnitude. Crystalline lens measurements revealed a similarly strong correlation between horizontal tilts of the crystalline lens and IOL ( r2 = 0.97, P < .01). However, IOL tilt along the vertical meridian may be more difficult to anticipate using crystalline lens measurements ( r2 = 0.78, P < .01) and showed no correlation with axial length ( r2 = 0.00, P = .92).

Conclusions: The Vtx-SSA may be used as an easy-to-interpret presurgical surrogate for estimating horizontal IOL tilt. Still, it does not account for more minor contributions of tilt in the vertical plane.

Keywords

Humans, Prospective Studies, Phacoemulsification, Lenses, Intraocular, Female, Lens Implantation, Intraocular, Aged, Tomography, Optical Coherence, Male, Sclera, Middle Aged, Aged, 80 and over, Artificial Lens Implant Migration, Lens, Crystalline

Published Open-Access

yes

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.