Language

English

Publication Date

1-1-2026

Journal

Pregnancy

DOI

10.1002/pmf2.70200

PMID

42597159

PMCID

PMC13344713

PubMedCentral® Posted Date

12-12-2025

PubMedCentral® Full Text Version

Post-print

Abstract

Introduction: Postpartum hemorrhage (PPH) is a major cause of maternal morbidity and mortality. Timely prediction may prevent adverse maternal outcomes, and efforts are needed to develop accurate predictive tools. A high-performing machine learning model to predict PPH using data from the US Consortium for Safe Labor (CSL) remains to be widely validated in contemporary clinical settings using electronic health record (EHR) data. Our goal was to evaluate the performance of the CSL PPH predictive model using EHR data across a large healthcare system in the Northeastern United States.

Methods: We conducted a retrospective cohort study across eight hospitals in the Northeastern United States between May 2015 and May 2024. We used the same sociodemographic, clinical diagnoses, family history, laboratory, and vital signs available on labor and delivery admission in the EHR that were used to train the original CSL model. The binary outcome was PPH, defined as estimated blood loss of 1000 mL or more at delivery or blood transfusion within 24 h postpartum. We then refit a new model using the original features to assess whether model performance could be further improved in our study population using the best-performing machine learning approach (extreme gradient boosting [XGBoost]) from the original CSL model. We evaluated model discrimination as measured using the area under the curve (AUC), feature importance, calibration, and decision analysis curves of both the original CSL model with external validation and the further refit model.

Results: Among 87,662 deliveries, the incidence of PPH was 7.7%. The original CSL model demonstrated modest discrimination for predicting PPH with an AUC of 0.60 (95% confidence interval [CI], 0.58-0.61). Refitting a new model with XGBoost resulted in improved discrimination with an AUC of 0.75 (95% CI, 0.74-0.76). Calibration analyses demonstrated that the refit model overestimated PPH risk across a range of predicted probabilities.

Conclusion: A previously developed PPH predictive model had substantially reduced performance with external validation using contemporary EHR data across an eight-hospital health system in the Northeastern United States, underscoring limited generalizability. These findings highlight the importance of external validation, local adaptation, and ongoing surveillance for assessing model performance before implementing predictive models clinically.

Keywords

electronic health records, external validation, machine learning, postpartum hemorrhage, risk prediction, XGBoost

Published Open-Access

yes

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.