Keywords

neonatal intensive care unit (nicu), catheter jamming, fracture, picc line complication, peripherally inserted central catheter (picc)

Abstract

Peripherally inserted central catheters (PICCs) have become popular over tunneled catheters in neonatal intensive care units (NICUs) due to their ease of use and convenience. Although rare, a PICC fracture can be a severe and potentially fatal complication. This narrative review aims to identify factors predisposing neonates to PICC fracture and related complications, such as catheter jamming, and explore strategies for preventing and detecting this complication. A thorough search of PubMed and Google Scholar was conducted using relevant keywords to identify articles discussing PICC fracture in neonates. The review encompassed English-language literature on PICC fracture in neonates, with additional pertinent publications identified through citation searching. The incidence of PICC fracture in neonates varies from less than 1% to 10%, with a higher risk associated with prolonged catheterization, lower gestational age and lower birth weight, and the use of multi-lumen catheters. PICC fractures can occur during insertion, maintenance, or removal. Factors such as catheter duration, gestational age, birth weight, and catheter type increase the risk of PICC fracture. Excessive syringe pressure, securement failure, and excessive force during removal are contributing factors. Catheter fatigue and thin-walled catheter design are common causes of breakage. Preventive measures include proper training of healthcare providers, regular monitoring, early recognition, and prompt catheter removal upon fracture. Preventing and detecting PICC fractures is crucial for neonatal safety. Vigilance during insertion, maintenance, and removal, along with care to avoid excessive force during removal and high pressure during flushing, can help prevent catheter breakage. More research is required to improve prevention strategies for PICC fractures in neonates.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.