Language

English

Publication Date

1-1-2026

Journal

Therapeutic Advances in Infectious Disease

DOI

10.1177/20499361261451368

PMID

42186600

PMCID

PMC13198637

PubMedCentral® Posted Date

5-22-2026

PubMedCentral® Full Text Version

Post-print

Abstract

Background: While the need for complete device removal is well-established for cardiovascular implantable electronic device (CIED) infections, there is insufficient evidence on the optimal duration of antimicrobial therapy.

Objectives: To examine how antimicrobial duration affects clinical outcomes of patients presenting with CIED-associated bacteremia and lead endocarditis.

Design: This is a retrospective cohort study conducted at a quaternary care hospital in Houston, TX, USA.

Methods: Patients who underwent device removal for a primary indication of bacteremia or lead endocarditis over a 10-year period were stratified by prescribed duration of antibiotics as ⩽2 weeks or >2 weeks post-extraction. Measured outcomes included all-cause mortality at 90 days, recurrent bacteremia, infectious complications, and hospital length of stay.

Results: Of 747 patients who underwent lead extraction at Baylor St. Luke's Medical Center between June 2013 and December 2023, 79 cases met the inclusion criteria. Baseline characteristics were similar between cohorts. Mean duration of antibiotics prescription was 12.6 versus 38.6 days. There was no observed difference in survival (HR 0.693, 95% CI 0.085-5.652, p = 0.438), recurrent bacteremia (7% vs 6%, p = 0.952), infectious complications (27% vs 30%, p = 0.817), and hospital length of stay (mean 9.9 vs 13.3, p = 0.360) between the ⩽2 weeks and >2 weeks cohort, respectively. Five patients had recurrence, all of whom had bacteremia from Staphylococcus aureus or Serratia sp. and an underlying left ventricular assist device or valve replacement.

Conclusion: Shorter duration of antibiotics after complete CIED removal had similar rates of mortality or recurrent bacteremia. Recurrence was associated with bacteremia from high-risk organisms with potential for secondary seeding of other cardiovascular prostheses. Larger prospective studies are needed to explore these findings.

Keywords

antibiotic duration, bacteremia, endocarditis, ICD, lead extraction, pacemaker

Published Open-Access

yes

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.