Publication Date

1-1-2020

Journal

Frontiers in Cardiovascular Medicine

DOI

10.3389/fcvm.2020.00089

PMID

32656246

PMCID

PMC7322993

PubMedCentral® Posted Date

6-22-2020

PubMedCentral® Full Text Version

Post-print

Published Open-Access

yes

Keywords

atrial fibrillation, stroke, left atrial appendage closure, Amplatzer Cardiac Plug, Amplatzer Amulet, WatchmanTM device

Abstract

Background: For patients with atrial fibrillation who are at high risk for bleeding or who cannot tolerate oral anticoagulation, left atrial appendage (LAA) closure represents an alternative therapy for reducing risk for thromboembolic events.

Objectives: To compare the efficacy and safety of the Amplatzer and WatchmanTM LAA closure devices.

Methods: A meta-analysis was performed of studies comparing the safety and efficacy outcomes of the two devices. The Newcastle-Ottawa Scale was used to appraise study quality.

Results: Six studies encompassing 614 patients were included in the meta-analysis. Overall event rates were low for both devices. No significant differences between the devices were found in safety outcomes (i.e., pericardial effusion, cardiac tamponade, device embolization, air embolism, and vascular complications) or in the rates of all-cause mortality, cardiac death, stroke/transient ischemic attack, or device-related thrombosis. The total bleeding rate was significantly lower in the WatchmanTM group (Log OR = −0.90; 95% CI = −1.76 to −0.04; p = 0.04), yet no significant differences was found when the bleeding rate was categorized into major and minor bleeding. Total peridevice leakage rate and insignificant peridevice leakage rate were significantly higher in the WatchmanTM group (Log OR = 1.32; 95% CI = 0.76 to 1.87; p < 0.01 and Log OR = 1.11; 95% CI = 0.50 to 1.72; p < 0.01, respectively). However, significant peridevice leakages were similar in both the devices.

Conclusions: The LAA closure devices had low complication rates and low event rates. Efficacy and safety were similar between the systems, except for a higher percentage of insignificant peridevice leakages in the WatchmanTM group. A randomized controlled trial comparing both devices is underway, which may provide more insight on the safety and efficacy outcomes comparison of the devices.