Publication Date

4-30-2024

Journal

JNCI Cancer Spectrum

Abstract

BACKGROUND: Traditional constraints specify that 700 cc of liver should be spared a hepatotoxic dose when delivering liver-directed radiotherapy to reduce the risk of inducing liver failure. We investigated the role of single-photon emission computed tomography (SPECT) to identify and preferentially avoid functional liver during liver-directed radiation treatment planning in patients with preserved liver function but limited functional liver volume after receiving prior hepatotoxic chemotherapy or surgical resection.

METHODS: This phase I trial with a 3 + 3 design evaluated the safety of liver-directed radiotherapy using escalating functional liver radiation dose constraints in patients with liver metastases. Dose-limiting toxicities were assessed 6-8 weeks and 6 months after completing radiotherapy.

RESULTS: All 12 patients had colorectal liver metastases and received prior hepatotoxic chemotherapy; 8 patients underwent prior liver resection. Median computed tomography anatomical nontumor liver volume was 1584 cc (range = 764-2699 cc). Median SPECT functional liver volume was 1117 cc (range = 570-1928 cc). Median nontarget computed tomography and SPECT liver volumes below the volumetric dose constraint were 997 cc (range = 544-1576 cc) and 684 cc (range = 429-1244 cc), respectively. The prescription dose was 67.5-75 Gy in 15 fractions or 75-100 Gy in 25 fractions. No dose-limiting toxicities were observed during follow-up. One-year in-field control was 57%. One-year overall survival was 73%.

CONCLUSION: Liver-directed radiotherapy can be safely delivered to high doses when incorporating functional SPECT into the radiation treatment planning process, which may enable sparing of lower volumes of liver than traditionally accepted in patients with preserved liver function.

TRIAL REGISTRATION: NCT02626312.

Keywords

Humans, Male, Female, Liver Neoplasms, Middle Aged, Aged, Tomography, Emission-Computed, Single-Photon, Liver, Radiotherapy, Image-Guided, Colorectal Neoplasms, Organ Size, Radiotherapy Dosage, Tomography, X-Ray Computed, Radiotherapy Planning, Computer-Assisted, Adult

Comments

Trial Registration: NCT02626312.

PMID: 38730548

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.