Faculty, Staff and Student Publications

Publication Date

9-1-2022

Journal

Journal of Applied Clinical Medical Physics

Abstract

Purpose: To develop a checklist that improves the rate of error detection during the plan review of automatically generated radiotherapy plans.

Methods: A custom checklist was developed using guidance from American Association of Physicists in Medicine task groups 275 and 315 and the results of a failure modes and effects analysis of the Radiation Planning Assistant (RPA), an automated contouring and treatment planning tool. The preliminary checklist contained 90 review items for each automatically generated plan. In the first study, eight physicists were recruited from our institution who were familiar with the RPA. Each physicist reviewed 10 artificial intelligence-generated resident treatment plans from the RPA for safety and plan quality, five of which contained errors. Physicists performed plan checks, recorded errors, and rated each plan's clinical acceptability. Following a 2-week break, physicists reviewed 10 additional plans with a similar distribution of errors using our customized checklist. Participants then provided feedback on the usability of the checklist and it was modified accordingly. In a second study, this process was repeated with 14 senior medical physics residents who were randomly assigned to checklist or no checklist for their reviews. Each reviewed 10 plans, five of which contained errors, and completed the corresponding survey.

Results: In the first study, the checklist significantly improved the rate of error detection from 3.4 ± 1.1 to 4.4 ± 0.74 errors per participant without and with the checklist, respectively (p = 0.02). Error detection increased by 20% when the custom checklist was utilized. In the second study, 2.9 ± 0.84 and 3.5 ± 0.84 errors per participant were detected without and with the revised checklist, respectively (p = 0.08). Despite the lack of statistical significance for this cohort, error detection increased by 18% when the checklist was utilized.

Conclusion: Our results indicate that the use of a customized checklist when reviewing automated treatment plans will result in improved patient safety.

Keywords

Artificial Intelligence, Checklist, Humans, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, automation, checklist, patient safety, quality assurance, risk assessment

DOI

10.1002/acm2.13694

PMID

35775105

PMCID

PMC9512344

PubMedCentral® Posted Date

6-30-2022

PubMedCentral® Full Text Version

Post-print

Published Open-Access

yes

Plum Print visual indicator of research metrics
PlumX Metrics
  • Citations
    • Citation Indexes: 9
  • Usage
    • Downloads: 1
  • Captures
    • Readers: 26
see details

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.