Faculty, Staff and Student Publications

Publication Date

8-30-2024

Journal

British Journal of Surgery

DOI

10.1093/bjs/znae165

PMID

39213397

PMCID

PMC11364140

PubMedCentral® Posted Date

8-30-2024

PubMedCentral® Full Text Version

Post-print

Abstract

Background: Several ablation confirmation software methods for minimum ablative margin assessment have recently been developed to improve local outcomes for patients undergoing thermal ablation of colorectal liver metastases. Previous assessments were limited to single institutions mostly at the place of development. The aim of this study was to validate the previously identified 5 mm minimum ablative margin (A0) using autosegmentation and biomechanical deformable image registration in a multi-institutional setting.

Methods: This was a multicentre, retrospective study including patients with colorectal liver metastases undergoing CT- or ultrasound-guided microwave or radiofrequency ablation during 2009-2022, reporting 3-year local disease progression (residual unablated tumour or local tumour progression) rates by minimum ablative margin across all institutions and identifying an intraprocedural contrast-enhanced CT-based minimum ablative margin associated with a 3-year local disease progression rate of less than 1%.

Results: A total of 400 ablated colorectal liver metastases (median diameter of 1.5 cm) in 243 patients (145 men; median age of 62 [interquartile range 54-70] years) were evaluated, with a median follow-up of 26 (interquartile range 17-40) months. A total of 119 (48.9%) patients with 186 (46.5%) colorectal liver metastases were from international institutions B, C, and D that were not involved in the software development. Three-year local disease progression rates for 0 mm, >0 and < 5 mm, and 5 mm or larger minimum ablative margins were 79%, 15%, and 0% respectively for institution A (where the software was developed) and 34%, 19%, and 2% respectively for institutions B, C, and D combined. Local disease progression risk decreased to less than 1% with an intraprocedurally confirmed minimum ablative margin greater than 4.6 mm.

Conclusion: A minimum ablative margin of 5 mm or larger demonstrates optimal local oncological outcomes. It is proposed that an intraprocedural minimum ablative margin of 5 mm or larger, confirmed using biomechanical deformable image registration, serves as the A0 for colorectal liver metastasis thermal ablation.

Keywords

Humans, Colorectal Neoplasms, Liver Neoplasms, Male, Retrospective Studies, Female, Middle Aged, Aged, Artificial Intelligence, Tomography, X-Ray Computed, Margins of Excision, Disease Progression, Radiofrequency Ablation

Published Open-Access

yes

znae258.pdf (78 kB)
Correction

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.