Faculty, Staff and Student Publications
Publication Date
8-19-2025
Journal
Cancers
DOI
10.3390/cancers17162697
PMID
40867326
PMCID
PMC12384636
PubMedCentral® Posted Date
8-19-2025
PubMedCentral® Full Text Version
Author MSS
Abstract
BACKGROUND: Stereotactic body radiation therapy (SBRT) has proven effective in controlling spinal lesions with minimal toxicity, primarily due to its ability to limit spinal cord dose. Recent advances in MR-linac (MRL) technology offer superior spinal cord visualization and real-time gating, which can facilitate dose escalation in spinal tumor treatment while maintaining safety.
PURPOSE: This study aimed to optimize motion management for spine SBRT on an MRL by analyzing patient-specific motion dynamics and evaluating the most effective registration structures. We hypothesized that baseline shifts (BLS) would improve delivery efficiency while maintaining spinal cord dose constraints. The goal was to establish displacement thresholds and assess the role of baseline shift correction adaptative planning in improving treatment delivery efficiency.
METHODS: Twelve patients underwent two MRI sessions on the MRL. The optimal registration structure was identified, and intrafraction motion was assessed to calculate delivery efficiency. Baseline shift (BLS) simulations were applied for five cases that showed significant motion and suboptimal delivery efficiency, and the dosimetric impact of the BLS was evaluated. The simulated BLS-based plan adaptation was implemented via a segment aperture morphing adapt-to-position workflow.
RESULTS: The most stable registration structure was the spinal canal plus three adjacent vertebrae. Cine imaging revealed average intrafraction motion (95th to 5th percentiles) of 0.8 ± 0.5 mm in the right-left (RL) direction, 0.9 ± 0.6 mm in the anterior-posterior (AP) direction, and 0.7 ± 0.5 mm in the SI direction. Simulated BLS improved delivery efficiency to >80% in all but one case, with a ±1 mm displacement threshold tolerance. While target coverage remained consistent after BLS simulation, the spinal cord dose increased by 7-60%, exceeding the 14 Gy constraint in three of the five simulated cases.
CONCLUSIONS: Cine imaging and BLS can enhance delivery efficiency in spine SBRT but may increase spinal cord dose. These findings underscore the need for careful patient selection, advanced motion management, and patient-specific BLS protocols.
Published Open-Access
yes
Recommended Citation
Ding, Yao; Salzillo, Travis C; Yeboa, Debra N; et al., "Optimizing Motion Management and Baseline Shifts in Magnetic Resonance-Guided Spine Stereotactic Body Radiation Therapy" (2025). Faculty, Staff and Student Publications. 5028.
https://digitalcommons.library.tmc.edu/uthgsbs_docs/5028
Included in
Bioinformatics Commons, Biomedical Informatics Commons, Genetic Phenomena Commons, Medical Genetics Commons, Oncology Commons