Faculty, Staff and Student Publications
Language
English
Publication Date
1-1-2025
Journal
Frontiers in Oncology
DOI
10.3389/fonc.2025.1731259
PMID
41716710
PMCID
PMC12913141
PubMedCentral® Posted Date
2-4-2026
PubMedCentral® Full Text Version
Post-print
Abstract
Background: Spatially fractionated radiotherapy (SFRT) delivered as lattice radiotherapy (LRT) creates high-dose 'vertex' subvolumes (VTVH) embedded within low-dose 'valley' regions (VTVL) to intensify intratumoral dose while minimizing radiation dose and toxicity to organs at risk (OARs). We developed a pencil-beam scanning (PBS) intensity modulated proton therapy (IMPT) LRT planning approach and dosimetrically compared it directly with contemporary photon-based volume modulated arc therapy (VMAT) LRT for liver cancer with bulky tumors.
Methods: Twenty-one retrospective liver cases were replanned in RayStation to a single fraction of 20 Gy to VTVH with explicit VTVL sparing (mean dose < 5Gy). Primary dosimetric endpoints were VTVH D80 and VTVL mean dose (analogous to mean valley dose), with secondary endpoints of VTVH/VTVL ratios (PVDR-like metrics at D80/D90/D100), VTVL D5/D80, GTV D10/D90, and planning risk volume (PRV) 0.03 cm³ hotspots. Statistical analysis consisted of paired tests (t-test or Wilcoxon signed-rank) after assessing data normality (Shapiro-Wilk tests) and using α=0.05 for significance.
Results: Compared with photon VMAT-LRT, IMPT-LRT significantly reduced VTVL mean dose (p< 0.00001) and increased VTVH D80 (p< 0.00001), yielding higher VTVH/VTVL ratios at D80/D90/D100 (all p< 0.00001). Gross tumor volume (GTV) heterogeneity (D20/D80) significantly increased with proton-LRT (p< 0.00001) and OAR hot-spot metrics (PRV D0.03cc) were comparable between both modalities (p=0.71).
Conclusions: A robust PBS proton-LRT planning approach was developed and compared to photon VMAT-LRT for large liver tumors. Our IMPT-LRT approach maximizes peak-to-valley separation and simultaneously maintains target coverage while significantly reducing valley dose, as compared to traditional VMAT-LRT. These findings support future prospective clinical evaluation.
Keywords
bulky tumor, hepatocellular carcinoma, lattice radiation therapy, liver cancer, peak-to-valley dose ratio, proton therapy, VMAT, spatially fractionated radiation therapy
Published Open-Access
yes
Recommended Citation
Li, Yuting; Martin-Paulpeter, Rachael M; Chung, Christine V; et al., "Novel Pencil-Beam Scanning Proton Lattice Radiation Therapy for the Treatment of Bulky Liver Cancer: Dosimetric Comparison With VMAT-Lattice Radiotherapy" (2025). Faculty, Staff and Student Publications. 5644.
https://digitalcommons.library.tmc.edu/uthgsbs_docs/5644
Included in
Bioinformatics Commons, Biomedical Informatics Commons, Genetic Phenomena Commons, Medical Genetics Commons, Oncology Commons