Faculty, Staff and Student Publications

Language

English

Publication Date

9-1-2025

Journal

Cancer Cytopathology

DOI

10.1002/cncy.70046

PMID

40889104

PMCID

PMC12401073

PubMedCentral® Posted Date

9-1-2025

PubMedCentral® Full Text Version

Post-print

Abstract

Background: Rapid on-site evaluation (ROSE) of thyroid fine-needle aspiration biopsy (FNAB) improves diagnostic adequacy and facilitates ancillary molecular testing. In this prospective, multireader study, the authors evaluated the feasibility of using whole-slide images (WSIs) for ROSE to determine specimen adequacy and preliminary categorization (according to The Bethesda System for Reporting Thyroid Cytopathology [Bethesda]) of image-guided thyroid FNABs compared with conventional light-microscopic (LM) examination of the same specimens in a referral cancer center.

Methods: The authors evaluated 98 ultrasound-guided thyroid FNAB cases. Smears were stained with Papanicolaou and Diff-Quik and were scanned at ×20 magnification using a Leica Aperio CS2 scanner. Five cytopathologists evaluated specimen adequacy and Bethesda categorization using WSI followed by LM assessment after a 2-week washout. Intraobserver and interobserver agreements were calculated using Cohen and Fleiss kappa (κ) statistics. Scan time, interpretation time, and the need for ×40 magnification or z stacking were recorded.

Results: In total, 463 slides were scanned, with mean scan time of 5.48 minutes. WSI quality was acceptable in most cases. Z stacking and ×40 magnification were requested in 23% and 14% of reviews, respectively. Intrareader agreement between WSI and LM examination was excellent (κ = 0.86-0.95). Inter-reader agreement was moderate for both WSI (κ = 0.48) and LM examination (κ = 0.56). Concordance was highest for Bethesda categories I and VI and lowest for categories III-V. Interpretation with WSI took significantly longer than with LM examination (p < .0001).

Conclusions: WSI is a feasible alternative to LM examination for ROSE of thyroid FNABs, with high intrareader agreement and comparable inter-reader agreement. The limited need for high magnification and z stacking supports its practical utility.

Keywords

Humans, Prospective Studies, Biopsy, Fine-Needle, Thyroid Neoplasms, Thyroid Gland, Thyroid Nodule, Observer Variation, Female, Male, Feasibility Studies, fine‐needle aspiration biopsy, rapid on‐site evaluation, telecytology, thyroid

Published Open-Access

yes

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.