Faculty, Staff and Student Publications

Language

English

Publication Date

11-1-2023

Journal

JSES International

DOI

10.1016/j.jseint.2023.07.016

PMID

37969532

PMCID

PMC10638596

PubMedCentral® Posted Date

8-8-2023

PubMedCentral® Full Text Version

Post-print

Abstract

Background: The Single-Incision Power Optimizing Cost-Effective Repair (SPOC) method reattaches the distal biceps tendon to its original posterior anatomic footprint and utilizes the anterior cortex of the supinated radius for fixation. The purpose of the study was to define the long-term complications and durability of the SPOC method.

Methods: Two hundred and eighteen patients underwent the SPOC repair of distal biceps ruptures from 2008 to 2020, with 185 having at least 1-year follow-up data. The average follow-up was 50.1 months. Information regarding smoking, body mass index, interval between injury and surgery, peripheral nerve injury, heterotopic ossification, vascular injury, re-rupture, chronic regional pain syndrome, fracture of the radius, loss of motion, pain with use, and deformity were acquired.

Results: No complication occurred beyond the third postoperative month. No patient complained of severe lateral antebrachial cutaneous nerve-related symptoms. Major complications exclusive of re-rupture occurred include 1 case of heterotopic ossification and 1 deep infection. Major complications with re-ruptures occurred in 9 patients (4.8%). Seven of the re-ruptures (78%) were associated with an unexpected forceful contraction within the first 4 weeks postop. All complications aside from 1 minor complication occurred in the chronic group. Long term follow-up revealed no re-ruptures and high satisfaction rate with return of strength, motion, and biceps profile.

Conclusion: The safety profile of the SPOC repair is consistent with those of other published repairs. Major complications were associated with prolonged intervals between injury and reconstruction. Re-ruptures were associated with worker's compensation status and patient noncompliance with postoperative protocols.

Keywords

SPOC, Distal bicep, Repair, Reconstruction, Complications, Strength measurement

Published Open-Access

yes

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.